background image

Safe area frequency output/discrete output load resistance values

Figure 8-12:

10000

9000

8000

7000

6000

5000

4000

3000

2000

1000

0

5

7

9

11

13

15

17

19

21

23

OPERATING REGION

Supply voltage VDC (Volts)

External pull-up resistor R

load

range

(Ohms)

R

max

= (V

supply

– 4)/0.003

Rmin = (Vsupply – 25)/0.006

Min. 100 W for supply voltage less than 25.6 Volts

25

27

29

I/O wiring for Model 1700 and Model 2700 transmitters with intrinsically safe outputs