Safe area mA output load resistance values

Figure 8-2:

1000

900

800

700

600

500

400

300

200

100

0

12

14

16

18

20

22

24

26

28

30

OPERATING REGION

Supply voltage VDC (Volts)

External resistor R

load

(Ohms)

R

max

= (V

supply

– 12)/0.023

Min. 250W and 17.5V required for HART communication

8.2

Safe area HART/analog single-loop wiring

Safe area HART/analog single-loop wiring

Figure 8-3:

A

B

c

A.

VDC

B.

R

load

(250–600 Ω resistance)

C.

HART-compatible host or controller

I/O wiring for Model 1700 and Model 2700 transmitters with intrinsically safe outputs