Integral installation

Figure 1-1:

Transmitter

Sensor

High-temperature flexible conduit – Some high-temperature meters come
preinstalled with a flexible conduit between the sensor and the transmitter. You do
not have to connect any wires between the transmitter and the sensor, but you do
need to mount the electronics separately and connect power and I/O wiring to the
transmitter.

High-temperature flexible conduit installation

Figure 1-2:

High-temperature flexible conduit installations use the same installation
instructions as 4-wire remote installations, except that the distance between the
sensor and the electronics is limited by the length of the flexible conduit.

4-wire remote – The transmitter is installed remotely from the sensor. You need to
mount the transmitter separately from the sensor, connect a 4-wire cable between
the transmitter and sensor, and connect power and I/O wiring to the transmitter.