Wiring the power supply

6.1

Wire the power supply

A user-supplied switch may be installed in the power supply line. For compliance with low-
voltage directive 2006/95/EC (European installations), a switch in close proximity to the
transmitter is required.
1.

Remove the transmitter housing cover.

2.

Open the warning flap.

3.

Connect the power supply wires to terminals 9 and 10.

Terminate the positive (line) wire on terminal 10 and the return (neutral) wire on
terminal 9.

Power supply wiring terminals

Figure 6-1:

A

B

C

A. Warning flap
B. Equipment ground
C. Power supply wiring terminals (9 and 10)

4.

Ground the power supply using the equipment ground, also under the warning flap.