background image

Cross-section of assembled cable gland with cable

Figure 4-12:

A

B

C

D

E

F

G

A

A. Cable
B. Sealing nut
C. Seal
D. Compression nut
E. Braided shield
F. Brass compression ring
G. Nipple

9.

Remove the junction box cover and core processor end-cap.

10.

At both the sensor and transmitter, connect the cable according to the following
procedure:

a. Insert the stripped end of each wire into the corresponding terminal at the

sensor and transmitter ends, matching by color (see

Table 4-6

). No bare wires

should remain exposed.

Note

For ELITE

®

, H-Series, T-Series, and some F-Series sensors, match the wire to the terminal

by the color identified on the inside of the sensor junction box cover.

Sensor and transmitter terminal designations

Table 4-6:

Wire color

Sensor terminal

Transmitter terminal

Function

Black

No connection

0

Drain wires

Brown

1

1

Drive +

Red

2

2

Drive –

Orange

3

3

Temperature –

Yellow

4

4

Temperature return

Green

5

5

Left pickoff +

Blue

6

6

Right pickoff +

Violet

7

7

Temperature +