Maximum cable lengths, Outputs option identification, 2 outputs option identification – Emerson MICRO MOTION 1700 User Manual

Page 9: 2 maximum cable lengths

Advertising
background image

Remote core processor with remote sensor installation type

Figure 1-6:

Core processor

Transmitter

4-wire cable

9-wire cable

Sensor

Junction box

1.1.2

Maximum cable lengths

The maximum cable length between flowmeter components that are separately installed
is determined by cable type. See

Table 1-1

.

Maximum cable lengths

Table 1-1:

Cable type

Wire gauge

Maximum length

Micro Motion 4-wire

Not applicable

1000 ft (300 m)

Micro Motion 9-wire

Not applicable

60 ft (20 m)

User-supplied 4-wire

VDC 22 AWG (0.35 mm

2

)

300 ft (90 m)

VDC 20 AWG (0.5 mm

2

)

500 ft (150 m)

VDC 18 AWG (0.8 mm

2

)

1000 ft (300 m)

RS-485 22 AWG (0.35 mm

2

) or

larger

1000 ft (300 m)

1.2

Outputs option identification

You must know your transmitter's output option to correctly install the transmitter.

Planning