10.2

Input/output signals

Input/output signals – Model 1700 transmitter with analog outputs

Table 10-2:

Type

Description

Output variables

Mass flow

Volume flow

Inputs/outputs

One active 4–20 mA output

One active frequency output

HART

Bell 202 signal is superimposed on the primary milliamp out-
put

WirelessHART available via THUM adapter

Input/output signals – Model 2700 transmitter with analog outputs

Table 10-3:

Type

Description

Output variables

Mass & volume flow

Net product content / flow

Temperature

Density

Concentration

Inputs/outputs

Not intrinsically safe

One active 4–20 mA output

One active frequency output

Frequency output can be configured as a discrete output

HART/WirelessHART

Bell 202 signal is superimposed on the primary milliamp out-
put

WirelessHART available via THUM adapter

HART communication is unavailable on Foundation fieldbus
and PROFIBUS-PA transmitter versions

Input/output signals – Model 1700 transmitter with intrinsically safe
outputs

Table 10-4:

Type

Description

Output variables

Mass flow

Volume flow

Inputs/outputs

One passive 4–20 mA output

One active frequency output

HART

Bell 202 signal is superimposed on the primary milliamp out-
put

WirelessHART available via THUM adapter

Specifications

110

Micro Motion

®

Model 1700 and 2700