10.4

Environmental limits

Environmental specifications

Table 10-9:

Type

Value

Ambient temperature limits

–40 to +140 °F (–40 to +60 °C)

Humidity limits

5 to 95% relative humidity, non-condensing at 140 °F (60 °C)

Vibration limits

Meets IEC68.2.6, endurance sweep, 5 to 2000 Hz, 50 sweep cy-
cles at 1.0 g

EMI effects

Complies with EMC Directive 2004/108/EC per EN 61326 Indus-
trial
Complies with NAMUR NE-21 (22.08.2007)

Ambient temperature effect on
analog outputs

On mA output: ±0.005% of span per °C

If possible, install the transmitter in a location that will prevent direct exposure to sunlight.
The environmental limits for the transmitter may be further restricted by hazardous area
approvals.

10.5

Physical specifications

Physical specifications

Table 10-10:

Type

Description

Mounting options

Field-mount

Integrally mounted to a Micro Motion F-Series or R-Series
sensor

Remotely mounted to any 4-wire or 9-wire Micro Motion
Coriolis sensor

Housing

NEMA 4X (IP66) polyurethane-painted cast aluminum

Weight (4-wire remote-mount
option)

8 lb (3.6 kg)

Weight (9-wire remote-mount
option)

14 lb (6.3 kg)

Cable gland entrances

1/2˝–14 NPT or M20

× 1.5 female conduit ports for outputs and

power supply
3/4˝–14 NPT female conduit port for sensor/core processor ca-
ble

Specifications

Installation Manual

113

Advertising
This manual is related to the following products: