Wire the transmitter to the sensor, 3 wire the transmitter to the sensor – Emerson MICRO MOTION 1700 User Manual

Page 26

Advertising
background image

Twisted pair construction.

Applicable hazardous area requirements, if the core processor is installed in a
hazardous area.

Wire gauge appropriate for the cable length between the core processor and the
transmitter.

Wire gauge

Table 3-1:

Wire gauge

Maximum cable length

VDC 22 AWG (0.35 mm

2

)

300 ft (90 m)

VDC 20 AWG (0.5 mm

2

)

500 ft (150 m)

VDC 18 AWG (0.8 mm

2

)

1000 ft (300 m)

RS-485 22 AWG (0.35 mm

2

) or larger

1000 ft (300 m)

3.3

Wire the transmitter to the sensor

1.

Connect the cable to the core processor as described in the sensor documentation.

2.

Feed the wires from the sensor through the conduit opening.

3.

Connect wires to the appropriate terminals on the mating connector.

Important

Never ground the shield, braid, or drain wire(s) at the transmitter.

Tip

You may find it easier to unplug the mating connector to connect the wires. If you do so,
remember to firmly reseat the mating connector and tighten the mating connector screws so
that the mating connector cannot accidentally come loose.

Mounting and sensor wiring for 4-wire remote installations

22

Micro Motion

®

Model 1700 and 2700

Advertising
This manual is related to the following products: