Sensor and transmitter terminal designations

Table 4-5:

Wire color

Sensor terminal

Transmitter terminal

Function

Black

No connection

0

Drain wires

Brown

1

1

Drive +

Red

2

2

Drive –

Orange

3

3

Temperature –

Yellow

4

4

Temperature return

Green

5

5

Left pickoff +

Blue

6

6

Right pickoff +

Violet

7

7

Temperature +

Gray

8

8

Right pickoff –

White

9

9

Left pickoff –

d. Tighten the screws to hold the wire in place.
e. Ensure integrity of gaskets, grease all O-rings, then replace the junction box and

transmitter housing covers and tighten all screws, as required.

4.3.1

Sensor and transmitter terminals

ELITE, H-Series, T-Series, and some F-Series sensor terminals

Figure 4-8:

D

I

H

F

E

A B C

G

A.

Violet

B.

Yellow

C.

Orange

D.

Brown

E.

White

F.

Green

G.

Red

H.

Gray

I.

Blue

Mounting and sensor wiring for 9-wire remote installations

38

Micro Motion

®

Model 1700 and 2700

Advertising