Sensor and remote core processor terminal designations

Table 5-7:

Wire color Sensor terminal Remote core processor terminal Function

Black

No connection

Ground screw (see notes)

Drain wires

Brown

1

1

Drive +

Red

2

2

Drive –

Orange

3

3

Temperature –

Yellow

4

4

Temperature return

Green

5

5

Left pickoff +

Blue

6

6

Right pickoff +

Violet

7

7

Temperature +

Gray

8

8

Right pickoff –

White

9

9

Left pickoff –

Notes

Ground the shield drain wires (the black wire) only on the remote core processor end,
by connecting it to the ground screw inside the lower conduit ring. Never ground to
the core processor’s mounting screw. Never ground the cable at the sensor junction
box.

Ground the cable braid on both ends, by terminating it inside the cable glands.

b. Tighten the screws to hold the wires in place.
c. Ensure integrity of gaskets, grease all O-rings, then replace the junction box

cover and remote core processor end-cap and tighten all screws, as required.