93

5. Measuring

NOTE

In the HSS Cordless Flash Mode, the backlight of the LCD screen dims and is only

illuminated for three seconds after measurement.

After the measurement, the meter enters the 90-second Standby Mode again. If you

need to measure again, fire the flash during this time.

I

f the measured values are stored in the memory, the Measurement Standby Mode is canceled.

If the icon stops blinking before the flash fires, repeat Steps 6 and 7.

To stop the Standby Mode, just touch the screen.

It is convenient to set the light meter in a fixed position during the measuring time. This

can be accomplished by mounting the meter on a tripod or stand using the tripod socket

on the bottom of the meter.

2)

Number of Pre-flash

For red-eye prevention and auto-flash light adjustment, some devices can pre-flash

before main flash burst.

With the normal setting, the light meter will measure the pre-flash bursts and not the main

flash burst. To take a successful reading, activate the pre-flash feature in the Tool Box.

Operation

1.

Touch the [Tool Box] Icon (

) on the Measuring Screen.

The Tool Box Screen is displayed.

7.

W

hen the Measuring Mode Icon (

) is blinking, release the shutter

button of the camera that is set to HSS Flash Mode to fire the flash unit.

When the flash light is detected, the measurement is made automatically and the

measured value (F-stop) is displayed.

Measuring Screen

Flash Component

Measured Value

(F-stop)