12. Troubleshooting

12.

Troubleshooting

If your meter is not operating properly, as you expect, please consult the following

conditions and attempt the suggested solutions before contacting Sekonic. Non-

operation can be due to incorrect, mis-setting of the meter or battery condition.

Should your meter be malfunctioning, please contact place where meter was

purchased or Sekonic for service and repair.

Condition

Possible reasons

What to do

The power does not turn

on. (No display)

Was the Power Button

5

pressed and held in for more

than one second?

Hold the Power Button

5

down

for more than one second.

Batteries installed properly (+/-)?

Check the display (+/-).

(

P4)

Batteries dead?

Replace the batteries. (

P8)

Battery terminals dirty?

Wipe them with a dry cloth.

Correct batteries being used?

Check the batteries.

(

P4)

The LCD screen doesn't

respond.

Is the screen locked?

Hold down the Menu Button

9

to

release the screen lock. (

P13)

The viewfinder does

not show the measured

value.

Is the light receiving method

Incident Light Mode? (The

display of measurement in

the viewfinder is available in

Reflected Light Mode only.)

Set the meter to Reflected Light

Mode with Function Button or

Tool Box Screen. (

P37

,

P39

)

Can not measure.

Is it connected to a PC with the

USB cable?

Remove- the USB cable.

(

P23)

Have Measuring Button and

Memory Button Functions been

switched?

Check the Custom Setting

Function and switch the

buttons if necessary. (

P5

,

P41

,

P157)

Is the measured flash duration

time longer than the input shutter

speed?

Slower the shutter speed than

the flash duration time and

measure again. (

P96)

Advertising