Sekonic Speedmaster L-858D-U Light Meter User Manual

Page 215

Advertising
background image

201

10. Specifications

Luminance

(in two significant digits)

Reflected light

0.10 cd/m

2

to 980,000 cd/m

2

0.03 to 290,000 fl

Calibration Constant

Incident light

Lumisphere C = 340

Flat diffuser (retracted lumisphere)

C = 250

Reflected light

K = 12.5

Display Range

ISO

ISO 3 to ISO 13,107,200 (in 1/3 steps), ISO 850

Shutter speed

Ambient light

30 min to 1/64,000 sec, 1/200, 1/400

(in 1, 1/2, and 1/3 steps)

Flash light

30 min to 1/16,000 sec, 1/75, 1/80,

1/90, 1/100, 1/200, 1/400

(in 1, 1/2, and 1/3 steps)

Flash duration time

1/40s to 1/55,500 sec (25 ms to 18 us)

t0.1 to t0.9 (in 0.1 steps)

Aperture

F0.5 to F128.9 (in 1 steps)

F0.5 to F152.4 (in 1/2 steps)

F0.5 to F161.2 (in 1/3 steps)

EV

Incident light

Reflected light

EV-73.9 to EV+103.8
EV-69.9 to EV+105.3

Frame rate (f/s)

1f/s to 1,000f/s

Plus 20 other user settings from 0.001f/s to 99,999.999f/s

Shutter angle

1° to 358°

Plus 20 other user settings from 0.001° to 360°

Analog display

T scale 4s to 1/2000s (in 1/3 steps)

F scale F1.0 to F90 (in 1/3 steps)

EV scale

-3EV to +3EV (incident light, in 1/3 steps)

-7EV to +7EV (reflected light, in 1/3 steps)
Illuminance lux

0 to 50,000 lx

Luminance cd/m

2

0 to 2,500 cd/m

2

(candela per square meter)

Contrast Function

-9.9EV to +9.9EV (in 0.1 steps)

Cumulative count

0 to 99 times (Maximum of 99 times for display, the

number of measurement is infinite)

Filter compensation value

-12.0EV to +12.0EV (in 0.1 steps)

Filter name compensation

selection

Up to four types can be used simultaneously.

Plus 30 user settings

Exposure compensation

-9.9EV to +9.9EV (in 0.1 steps)

User calibration

-1.0EV to +1.0EV (in 0.1 steps)

Advertising