104

5. Measuring

NOTICE

● The flash duration time and graph are displayed in the Flash Duration Analysis

Mode, however, they cannot be stored in the memory.

They are cleared if the Measuring Mode is changed or the POWER switch is turned

OFF.

The incident light measurement can only be used in Flash Duration Analysis Mode.

When the synchro cord is connected to the Synchro Terminal

b

or when the

meter's Power Button

5

is pressed, the flash may fire.

● Also, the flash may not fire when the trigger voltage is very low. In such a case,

follow "5-4-1 Flash Duration Analysis Cordless Mode".

(

P95)

NOTE

When the measured value display area is touched, both flash waveform graph and

measured value are displayed. When it is touched again, the display returns to the

previous screen.

Measuring Screen

Flash Duration Analysis Cordless Mode

Flash Waveform Graph Screen

Touching the

Measured value

area changes

the display.

* The Graph Screen cannot be used to make measurements.

Measure the flash light characteristics in a darkroom without ambient light.