2) contrast function – Sekonic Speedmaster L-858D-U Light Meter User Manual

Page 135

Advertising
background image

121

6. Functions

Operation

1.

Rotate the Lumisphere Retracting Ring

1

.

Turn the Lumisphere Retracting Ring

1

to aligh the dot to the

retracted mark (

) position.

Only the light source can be measured by setting the light
receptor to the retracted lumisphere.

2.

Turn ON the main light source only.

Turn OFF the second light source.

3.

Press the Measuring Button

6

.

Point the light receptor at the main light source from the subject position to make a
measurement.

Lumisphere

Retracting Ring

1

Retracted (

)

2)

Contrast Function

This function is useful for checking studio lighting or illumination unevenness. This

function is also convenient when you check the difference in luminance between the

intermediate value and the highlight and/or shadow value for landscape shooting.

While you are holding down the Measuring Button

6

at the comparison position after

defining the measured value at a specific point as the standard value, a difference

between the standard value and the value at the comparison position is displayed with an

EV value (difference in stops), and the current measured value is displayed on the analog

scale.

*

If there are no values in the memory, the standard value will be the last measured value.

If there are values in the memory, the standard value will be the average of all the values

saved in the memory.

The example of lighting ratio using the Contrast Function

(In T Priority Mode in the incident light system)

When you want to measure the lighting ratio between the main and second light sources,

lower the lumisphere to use the Retracted Lumisphere Function.