103

5. Measuring

5.

Set the ISO sensitivity value on the [ISO] Icon.

(

P197)

6.

Set the shutter speed on the [T] Icon.

(

P197)

Measuring Screen

Setting Value

NOTICE

● Make sure that the settings are within the specifications

of the camera and flash system.

● If the measured flash duration time is longer than the

input shutter speed, an appropriate F-stop cannot be

measured. The yellow "Under" indication appears.

In this case, slower the shutter speed than the flash

duration time and measure again.

7.

Set the Flash Duration Analysis t value.

(

P105)

8.

Press the Measuring Button

6

.

The flash will fire and the measured value (F-stop) will be displayed.

Measuring Screen

Flash Duration Time

Flash Component

Measured Value

(F-stop)