6. Functions

4.

Touch the Set Average/Contrast Function Icon (

).

The "Ave" symbol appears on the screen.

When the Contrast Function is active, the Set Average/Contrast Function Icon (

) is

highlighted (

).

The measured value of the main light source is saved in the memory as the

standard value.

Measuring Screen

Measuring Screen

Measured

Value

Set Average/Contrast

Function Icon

The Contrast Function is active.

Memory

Count

"Ave" Symbol

Reference

Value

5.

Turn ON the second light source only.

Turn OFF the main light source.

6.

Hold down the Measuring Button

6

.

Point the light receptor at the second light source from the subject position to make a

measurement. While holding down the Measuring Button

6

, the difference between the

standard value of the main light source and the second light source being measured is

displayed in terms of an EV value. Then, the standard value and the measured value at
the compared position are displayed, and you will be able to obtain the contrast ratio.

7.

Release the Measuring Button

6

.

The Contrast Function is released. And the standard value is displayed at the

position of the measured value area.

8.

Touch the Set Average/Contrast Function Icon (

) again.

The Contrast Function is cleared, and the "Ave" symbol disappears from the

screen. The last measured value when the Measuring Button

6

is released is

displayed.

The standard value is saved in the memory as "

1". Clear the memory when you want

to use the Contrast Function with a new standard value.

(