General characteristics, Power requirements, Cooling requirements – HP E1418A User Manual

Page 113

Advertising
background image

General

Characteristics

Settling Time:

300

µ

S (+full scale to –full scale step, single channel, to accuracy listed

previously)

Isolation (for isolated channels):

42 Vdc/42 V peak (channel-to-chassis or channel-to-channel)

Synchronization:

Software commands, External TTL trigger, or VXIbus TTL Trigger lines
Single channel or multiple channel

VXI Specification:

Device Type: A16 or A24, D16, slave only, register-based

Power

Requirements

Current Required (Amps)

Configuration

+ 5 V

DC

+ 5 V

Dynamic

+ 12 V

DC

+ 12 V

Dynamic

+ 24 V

DC

+ 24 V

Dynamic

– 24 V

DC

– 24 V

Dynamic

8 Channel

Non-Isolated

0.70

0.01

0.04

0.01

0.44

0.01

0.44

0.01

8 Channel

Isolated

0.75

0.01

0.04

0.01

0.88

0.01

0.00

0.00

16 Channel

Non-Isolated

1.25

0.01

0.04

0.01

0.88

0.01

0.88

0.01

16 Channel

Isolated

1.40

0.01

0.04

0.01

1.60

0.01

0.00

0.00

Cooling

Requirements

For a 10

°

C rise

Air Flow

P

Avg

Watts/slot

8 Channel

configurations

2.0

liters/second

0.10 mm H

2

O

25.4

16 Channel

configurations

3.9

liters/second

0.18 mm H

2

O

49.0

112 HP E1418A Specifications