Source n :current[:level]:triggered[:amplitude, Source – HP E1418A User Manual

Page 88

Advertising
background image

SOURce

n

:CURRent[:LEVel]:TRIGgered[:AMPLitude]

SOURce

n

:CURRent[:LEVel]:TRIGgered[:AMPLitude] <

value

| MIN | MAX | DEF>

outputs the current set in value at channel n when the trigger conditions are satisfied and
the output relay is closed. Use this command to synchronize multiple channel outputs.

Parameters

Parameter

Name

Parameter

Type

Range of

Values

Default

SOURce

n

keyword

1 to 8 or 1 to 16

1

<

value

>

numeric (float 32) or

discrete

-0.02 Amps to +0.02 Amps or

MIN | MAX | DEF

0

Comments

In the keyword,

SOURce

n, the valid range of n is:

1 to 8 for

E1418A, E1418A Option 002

1 to 16 for

E1418A Option 001, E1418A Option 003.

Values of n outside these ranges will generate an error.

The

<

value

>

parameter is a floating point 32-bit number in the range of -0.02 A

to +0.02 A.

MIN

sets -0.02 Amps.

MAX

sets +0.02 Amps.

DEF

sets 0 Amps.

This command sets channel n to output the current specified following a valid
trigger condition. Following this command, the trigger system must be enabled
using an

INITiate

command. See the

TRIGger

subsystem discussion on page 54

for additional information.

If the module is in a wait-for-trigger state (

INIT

has been received) when this

command is received, an error is generated.

The output state of the channel must be enabled and the trigger event satisfied for
the current to appear at the output terminals.

If the channel is in the voltage mode when this command is received, an error is
generated.

Related Commands:

SOURce

n

:CURRent[:LEVel]:TRIGgered[:AMPLitude]?

,

SOURce

n

:FUNCtion:MODE CURRent

,

OUTPut

n

[:STATe]

SOURce

Chapter 3

HP E1418A SCPI Command Reference 87

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Advertising