Diagnostic:calibration:output[:mode, Diagnostic:configure, Diagnostic – HP E1418A User Manual

Page 78

Advertising
background image

DIAGnostic:CALibration:OUTPut[:MODE]?

DIAGnostic:CALibration:OUTPut[:MODE]?

queries the voltage calibration path

for the module.

Parameters

Returns: string.

Comments

The returned string will be one of

CALB

or

CHAN

.

DIAGnostic:CONFigure?

DIAGnostic:CONFigure?

returns six 16-bit words indicating the present settings of

the module.

Parameters

Returns: six unsigned 16-bit integers (uint16).

Comments

This query returns six 16-bit words with the following meanings:

Integer

Returned

Meaning

1st

Expansion Board ID in the form: 0 = present, 7 = none

(expansion board contains channels 9–16).

2nd

Terminal Module ID in the form:

0 = screw type, 7 = none or other.

3rd

Isolated/Non-Isolated Channel Status

A bit set to 0 indicates an isolated channel.

A bit set to 1 indicates a non-isolated channel or no plug-on module

installed (DO NOT operate the module without a plug-on module).

Bits 0–15 correspond to channels 1–16, respectively*.

4th

Channel Mode

A bit set to 0 indicates a current output channel.

A bit set to 1 indicates a voltage output channel.

Bits 0–15 correspond to channels 1–16, respectively*.

5th

Channel Output State

A bit set to 0 indicates the channel output relay is closed.

A bit set to 1 indicates the channel output relay is open.

Bits 0–15 correspond to channels 1–16, respectively*.

6th

Channel Mode Programmable State (P/J Jumper)

A bit set to 0 indicates a channel is not programmable.

A bit set to 1 indicates a channel is programmable.

Bits 0–15 correspond to channels 1–16, respectively*.

* For 8 channel configurations, the upper 8 bits of integers 3, 4, 5, and 6 are set to 1’s.

DIAGnostic

Chapter 3

HP E1418A SCPI Command Reference 77

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Advertising