Termination Less than 10 feet (3 meters) from ridge

Termination More than 10 feet (3 meters) from ridge

Less than 10 feet (3 meters)

More than 10' (3 meters)

2' (60cm)

Min.

3' (90cm) Min.

3' (90cm) Min.

Testing & Lighting Instructions

1. Turn on main gas valve. Remove the lower front cover

and the service panel above the control panel. Drop the

control panel and leak test all fittings and connections

upstream from the service valve located on the redundant

combination gas valve. Should any gas leaks be detected,

turn OFF main gas valve, correct the problem and retest.

2. Open shutoff valve located on the redundant combination

gas valve. Activate control panel and set to desired

temperature. The pilot and burner is now ignited by direct

spark. Check all fittings again and correct any leaks and

recheck.

Replace all service panels and covers before operation.

NOTE: All electronic ignition systems are supplied with a

redundant gas valve. Therefore, the unit is not supplied with

an external pressure regulator.

NOTE: During installation there will be air in the gas line, this

air will have to bleed off before ignition can be established.

The electronic ignition system has a ninety second lock-out

as a safety device on all units. Therefore, several attempts

may be required before pilot ignition is established, wait five

minutes after each attempt.

FOR YOUR SAFETY: KEEP YOUR APPLIANCE AREA FREE FROM

COMBUSTIBLES.

TO CONSERVE ENERGY:

Do not waste energy by leaving controls at high temperature

settings during idle periods. Lower settings will keep

oven warm and ready for next use period. Master 400

Series controls have an auto setback feature that is user

programmable to help with these applications.