PROBES

Oven Cavity Probe

Resistance vs . Temperature Chart For Internal Oven Cavity

Temperature Sensor .

The chart below will provide the Ohms at various

temperatures. This will enable you to determine if the

temperature probe is operable.

The chart is degrees Fahrenheit.

TEMP

10°

20°

30°

40°

50°

60°

70°

80°

90°

932

953

974

995

1016

1038

1059

1080

1101

1122

100°

1143

1163

1184

1205

1226

1247

1267

1288

1309

1329

200°

1350

1370

1391

1411

1432

1452

1472

1493

1513

1533

300°

1553

1574

1594

1614

1634

1654

1674

1694

1714

1733

400°

1753

1773

1793

1813

1832

1852

1871

1891

1911

1930

500°

1949

1969

1988

2008

2027

2046

2065

2085

2104

2123

Resistance Readings

77°F

=

1000 ohms

100°F =

1103 ohms

200°F =

1350 ohms

300°F =

1554 ohms

350°F =

1654 ohms

400°F =

1753 ohms

NOTE: If the cavity core probe is used, the core probe Led will

be lit on the control panel, the temperature of the product

will be displayed if the product is about 32°F.

The programmed range for the core probe is 100°F to 200°F.

Cavity Core Probe (455 Only)