Installation – Garland 200 User Manual

Page 8

Advertising
background image

Page 8

Part # MCOSM06 Rev 1 (11/03/08)

INSTALLATION

Installation Notes:

Combustible and Non-Combustible Wall Clearance: Side:

1.0" (25 mm) Rear: 3.0" (76 mm)

NOTE: Adequate clearance must be provided for servicing

and proper operation.

The importance of the proper installation of Commercial

Gas Cooking Equipment cannot be over stressed. Proper

performance of the equipment is dependent, in great part,

on the compliance of the installation with the manufacturer's

specifications. Installation must conform to local codes or,

in the absence of local codes, with the National Fuel Code,

ANSI Z223.1, Natural Gas Installation Code, CAN/CGA-B149.1,

or the Propane Installation Code, CAN/CGA-B149.2, as

applicable.

Before assembly and connection, check gas supply.

A. The type of gas for which the unit is equipped is stamped

on the data plate located behind lower front panel.

Connect a unit stamped "NAT" only to natural gas;

connect a unit stamped "PRO" only to propane.

B. If it is a new installation, have gas authorities check meter

size and piping to assure that the unit is supplied with

sufficient amount of gas pressure required to operate the

unit.

C. If it is additional or replacement equipment, have gas

authorities check pressure to make certain that existing

meter and piping will supply fuel at the unit with not

more that 1/2" water column pressure drop.

NOTE: When checking pressure be sure that all other

equipment on the same gas line is on. A pressure regulator

is supplied with GARLAND Convection Ovens. Regulator is

preset to deliver gas at pressure shown on the rating plate.

The appliance and its individual shut-off valve must be

disconnected from the gas supply piping system during

any pressure testing of that system at test pressures in

excess of 1/2 PSI (3.45 kPa).

The appliance must be isolated from the gas supply

piping system by closing its individual manual shut-off

valve during any pressure testing of the gas supply piping

system at test pressures equal to or less than 1/2 PSI

(3.45 kPa).

Installation Of Ovens Equipped With Casters

A. For an appliance equipped with casters, the installation

shall be made with a connector that complies with the

Standard for Connectors for Movable Appliances, ANSI

Z21.69 or Connectors for Moveable Gas Appliances,

CAN/CGA-6.16, and a quick-disconnect device that

complies with the Standard for Quick-Disconnect Devices

for Use With Gas Fuel, ANSI Z21.41, or Quick-Disconnect

Devices for Use with Gas Fuel, CAN1-6.9, and adequate

means must be provided to limit the movement of the

appliance without depending on the connector and the

quick-disconnect device or its associated piping to limit

the appliance movement and the location(s) where the

restraining means may be attached to the appliance shall

be specified.

B. The front casters of the unit are equipped with brakes

to limit the movement of the oven without depending

on the connector and any quick-disconnect device or its

associated piping to limit the appliance movement.

C. The restraint can be attached to the unit near the gas inlet.

If the restraint is disconnected, be sure to reconnect the

restraint after the oven has been returned to its originally

installed position.

Installation Of Double Deck Models

A. Position insert in bottom leg opening and tap insert up

into leg till it seats at collar. Attach six inch (6") legs to

lower oven section. Raise unit or lay on its left side. Place

the front legs on the oven so as to line up with four (4)

attaching bolt holes. Secure leg to oven frame using (4)

3/8-16 x 3/4 bolts and washers provided. Repeat at rear of

unit.

B. Remove lower front cover of top deck (located under oven

doors). Raise top deck into place and line up body sides

and back of the unit. Fasten the rear of the units together,

with the stacking bracket, as shown, using (6) 1/4-20

machine screws, lock washers and nuts, (provided).

C. Install the interconnecting flue parts, carefully following

the instructions contained in the stacking kit. Pay

particular attention to the type of ovens you are stacking

and be sure to follow the corresponding instructions.

Advertising