Operation – Garland 200 User Manual

Page 12

Advertising
background image

Page 12

Part # MCOSM06 Rev 1 (11/03/08)

OPERATION

Master 200 Mechanical Control with Timer
In Off Mode:

When the oven is off, there are no lights or indicators.

Start Up:

Press the Cook/Off/Cool Down rocker switch to the "Cook"

position. The green lamp will light indicating the oven is

powered in cook mode.

The oven will begin to heat to the temperature set on the

thermostat dial. The amber lamp will light indicating the heat

is active. As the heat cycles on and off to maintain the set

temperature this light will go on and off accordingly.

The door must be closed for the oven to operate in cook

mode. Opening the door will cause the heat to stop. The

motor and fan will shut off. This is a safety feature.

Fan Speed:

The fan speed can be either high (1725 RPM) or (1150 RPM).

The fan speed is controlled by the left rocker switch marked

high and low.

Lights:

The oven lights are activated by pressing the light switch on

the control panel. This is a momentary switch and the lights

will stay lit as long as this button is held in the on position.

Lights will work whenever there is electrical power connected

to the oven.

Cool Down:

Pressing the Cook/Off/Cool Down rocker switch to the Cool

Down position activates the fan and motor to cool the oven

cavity. The door must be open slightly for the fan and motor

to start. The heat is not active in this mode.

Optimal cool down will be achieved with the door open

slightly. Opening the door too far will shut the fan and motor

off. This is a patented safety feature.

Pressing the button to the OFF position cancels the cool

down and turns the oven off.

Temperature:

The temperature range is from 150°F to 500°F (66°C to 250°C)

is controlled by rotating the temperature dial and aligning the

indicator to the desired temperature.

Timer:

The timer is set by rotating the dial clockwise aligning the

indicator to the desired time cycle. The timer will count down

from 2 minutes to 60 minutes. At the end of the timing cycle

the buzzer will sound. The buzzer is turned off by rotating the

dial counter-clockwise to the off position as shown on the

control panel.

Advertising