Display, Key pad test – Garland 200 User Manual

Page 52

Advertising
background image

Page 52

Part # MCOSM06 Rev 1 (11/03/08)

KEY PAD TEST

Key

#9

Key

#5

Key

#1

Key

#10

Key

#6

Key

#2

Key

#12

Key

#8

Key

#4

Key

#11

Key

#7

Key

#3

DISPLAY

Ribbon

Connector

PIN DETAIL

VIEWED FRON FRONT

PIN NUMBERS

On Ribbon

Connector

7 6 5 4 3 2 1

KEYPAD & TEST

POINTS VIEWED

FRON FRONT

PIN- OUT TEST POINTS

Key #

PIN-OUTS

OVERLAY

MARKINGS

1

1 & 4

SET BACK

2

1 & 5

COOL DOWN

3

1 & 6

PROGRAM

4

1 & 7

ACTUAL TEMP

5

2 & 4

CAVITY LIGHT

6

2 & 5

FAN LOW

7

2 & 6

COOK / HOLD

8

2 & 7

SET

9

3 & 4

ON / OFF

10

3 & 5

FAN HIGH

11

3 & 6

PULSE

12

3 & 7

START/CANCEL

Between the above pin test points on the ribbon connector,

there should be continunty when the corresponding key is

pressed.

EXAMPLE: When Key # 1 is pressed and held, there should be

continunity between pins 1 & 4 at the ribbon cable.

NOTE: The keypad must be attached to the control panel

bezel when tested . The keypad is grounded to the panel to

complete the circuit . Disconnec the ribbon connector from

the SMART BOARD / CONTROLLER to gain better access to

teest points .

Not all overlays will have the above-indicated markings .

Advertising