Problem

Possible Cause

Corrective Action

Fan will not run

A. No Power to Unit

A. Turn Power on

B. No power to motor from relay board

B.

Check for voltage from relay board to motor

C. Micro Switch Not closing

C.

Check micro switches

Button on key pad not

responding

A. Loose ribbon connection between

key pad and smart board

A. Check that ribbon connection from key pad is

attached to smart board

B. Faulty key pad

B.

Refer to key pad testing procedure on bulletin

#B-107-2001

'Prob' in display

A. Probe disconnected

A. Reattach probe

B. Probe has failed

B.

Confirm ohm resistance of probe. Refer to cavity

probe chart for readings.

C.

Check for continuity between probe connection

at relay board, probe harness & probe

Unit will not shut off

A. Cavity temperature above 150°F

A. Normal operation. Unit will not go to Off until

cavity temperature is below 150°F

No HIGH speed but

HIGH speed LED is

illuminated on key pad

A. Bad relay board

A. CR3 on relay board should be on, if not check

for 24VDC ±10% at pins 5 & 7 at relay board. If

voltage present replace relay board

B. Bad smart board

B.

Check for 24VDC ±10% at pins 5 & 7 at relay

board. If voltage is not present replace smart

board

No LOW speed but

LOW speed LED is

illuminated on key pad

A. Bad relay board

A. CR4 on relay board should be on, if not check

for 24VDC ±10% at pins 5 & 8 at relay board. If

voltage present replace relay board

B. Bad smart board

B.

Check for 24VDC ±10% at pins 5 & 8 at relay

board. If voltage is not present replace smart

board

Unit will not heat.

DOOR shown in

display

A. Open circuit on upper door switch

A. Unplug unit from supply. With door closed

between NO and COM switch should be open.

B.

With door open to 30° angle switch should be

closed

C.

With door open all the way switch should be

closed.

Ignition - Lighting

problems

A. Incorrect gas pressure or gas turned

off

A. Check incoming gas pressure

B. Various faults possible

B.

Refer to trial and ignition flow chart in Section

Two of this manual

Unit will not turn

ON when button is

pushed, display reads

OFF

A. Loose ribbon connection between

key pad and smart board

A. Check connection

B. Faulty key pad

B.

Refer to key pad testing procedure on bulletin

#B-107-2001

No Display

A. No power to smart board

A. Check for 24 VAC between pins 1 and 3 on smart

board. If voltage present check for 24 VAC at pins

1 and 3 at relay board.

B. No power to relay board

B.

Check for 24 VAC into relay board and 24 VAC

out of relay board between pins 1 and 3 on relay

board