Garland 200 User Manual

Page 42

Advertising
background image

Page 42

Part # MCOSM06 Rev 1 (11/03/08)

6. Confirm the temperature inside the oven cavity with your

meter and that shown on the temperature dial.

7. If an adjustment is required, loosen the set screw

and position the mark on the temperature dial to the

temperature shown on your meter.

8. Tighten set screw down.

9. Repeat as required (once is usually enough).

10. Fully tighten both set screws.

Electric Units – Calibration 300 Series

1. Remove the temperature dial from the potentiometer.

2. Turn the potentiometer to its lowest setting (fully counter

clock-wise).

3. Place the temperature dial back on the potentiometer.

4. Align the mark on the temperature dial to the top left

edge of the "F": on the left of the temperature dial and

sung down one of the set screws. Do Not fully tighten yet.

5. Set the temperature to 300°F and allow the unit to cycle 3

times.

6 Confirm the temperature inside the oven cavity with your

meter and that on the temperature dial.

7. If adjustment is required, loosen the set screw and

position the mark on the temperature dial to the

temperature shown on your meter.

8. Tighten set screw down.

9. Repeat as required (once is usually enough).

10. Fully tighten both set screws.

Electric Units – 200 series

1. Remove the temperature dial from the potentiometer.

2. Turn the potentiometer to its highest setting (fully clock

wise).

3. Place the temperature dial back on the potentiometer.

4. Align the mark on the temperature dial 1/4" PAST the

500°F marking on the overlay and snug down one of the

set screws. Do NOT fully tighten yet.

5. Set the temperature to 300°F and allow to cycle 3-times.

6. Confirm the temperature inside the oven cavity with your

meter and that on the temperature dial.

7. If adjustment is required, loosen the set screw and

position the mark on the temperature dial to the

temperature shown on your meter.

8. Tighten set screw down.

9. Repeat as required (once is usually enough).

10. Fully tighten both set screws.

Advertising