Resistance Vs. Temperature Chart

For Internal Oven Temperature Sensor

The Chart below will provide the Ohms at various

temperatures. This will enable you to determine if the

temperature probe is operable.

The chart is in degrees Fahrenheit.

TEMP

10°

20°

30°

40°

50°

60°

70°

80°

90°

932

953

974

995

1016

1038

1059

1080

1101

1122

100°

1143

1163

1184

1205

1226

1247

1267

1288

1309

1329

200°

1350

1370

1391

1411

1432

1452

1472

1493

1513

1533

300°

1553

1574

1594

1614

1634

1654

1674

1694

1714

1733

400°

1753

1773

1793

1813

1832

1852

1871

1891

1911

1930

500°

1949

1969

1988

2008

2027

2046

2065

2085

2104

2123

200 & 300 SERIES CONTROLLERS CALIBRATION

Both the 200 & 300 series controllers use a 0 to 10.25k OHM

potentiometer. First check the sweep on the potentiometer

between the middle wire and one of the outside wires

for a gradual increase or decrease in the resistance as the

potentiometer stem is turned.

Gas Units – Calibration 300 Series

1. Remove the temperature dial from the potentiometer.

2. Turn the potentiometer to its lowest setting (fully counter

clock-wise).

3. Place the temperature dial back on the potentiometer.

4. Align the mark on the temperature dial to the top left

edge of the 'F': on the left of the temperature dial and

sung down one of the set screws. DO NOT fully tighten

yet.

5. Set the temperature dial to 150°F and allow the oven

cavity for reach set temperature.

6. Confirm the temperature inside the oven cavity with you

meter and that shown on the temperature dial.

7. If an adjustment is required, loosen the set screw

and position the mark on the temperature dial to the

temperature shown on your meter.

8. Tighten set screw down.

9. Repeat as required (once is usually enough).

10. Fully tighten both set screws.

Gas Units – Calibration 200 Series

1. Remove the temperature dial from the potentiometer.

2. Turn the potentiometer to its highest setting (fully clock-

wise).

3. Place the temperature dial back onto the potentiometer.

4. Align the mark on the temperature dial 1/4" PAST the

500°F marking on the overlay and snug down one of the

set screws. Do NOT fully tighten yet.

5. Set the temperature dial to 159°F and allow the oven

cavity to reach set temperature.