21555 hot-swap insertion and removal – Intel 21555 User Manual

Page 75

Advertising
background image

21555 Non-Transparent PCI-to-PCI Bridge User Manual

75

Initialization Requirements

When the INS_STAT bit is cleared, the card is ready for normal operation. When l_stat continues
to be sampled low, that indicates that the ejector handle is closed (and the micro-switch is open),
meaning the card remains fully inserted. The 21555 enters the Normal Operation state.

Figure 12. 21555 Hot

-

Swap Insertion and Removal

A8068-01

LOCAL_PCI_RST# = Deasserted AND
HEALTHY# = Asserted

Switch = Unlatched

Switch = Latched

Switch =

UnLatched

Switch =

Latched

Software clears INS

1 H/W Connected

Switch =

UnLatched

Switch =

Latched

Switch = Latched

LOCAL_PCI_RST#

Asserted (anytime)

0 H/W Disconnected

Board (and HS_CSR)

Invisible via PCI

INS = 0 (Armed)
EXT = 0 (Not Armed)
LOO = Initially 0
LED = LOO
EIM = Initially 0
ENUM# = Z

4b Insertion

INS = 0 (Armed) DETECT
EXT = 1
LOO =1/0
LED = LOO
EIM = 1/0
ENUM# = EIM

2a INS ENUM#

INS = 1
EXT = 0 (Not Armed)
LOO = 1/ 0
LED = LOO
EIM = 1/ 0
ENUM# = EIM

Switch = Unlatched

3 Installed

INS = 0 (Not Armed)
EXT = 0 (Armed)
LOO = 1/ 0
LED = LOO
EIM = 1/ 0
ENUM# = Z

2b Extraction

INS = 1

DETECT

EXT = 0 (Armed)
LOO = 1/ 0
LED = LOO
EIM = 1/ 0
ENUM# = EIM

Switch = Latched

Software clears EXT

Switch = Unlatched

INS = 0 (Not Armed)
EXT = 1
LOO = 1/ 0
LED = LOO
EIM = 1/ 0
ENUM# = EIM

LOCAL_PCI_RST# asserted
at any time and at any state
puts the interface in State 0

4a EXT ENUM#

INS = 0 (Armed)
EXT = 0 (Not Armed)
LOO = 1/ 0
LED = LOO
EIM = 1/ 0
ENUM# = Z

5 Extracted

Software

clears INS,

ENUM# may

go to Z

momentarily.

Software

clears EXT,

ENUM# may

go to Z

momentarily.

Advertising