Back panel components – I-Tech Company CMS 6R4 Series User Manual

Page 12

Advertising
background image

2-2

CMS-6R4 Series - User’s Guide

2.2. Back Panel Components

Power Inlet and Circuit Breaker: An AC inlet and circuit breaker

which supply power to the CMS-6R4. Includes cable keeper (not shown.)
Model CMS-6R4 (120 VAC): IEC-320-C14, 100 - 120 VAC Power

Inlet, 15 Amp Circuit Breaker.

Model CMS-6R4-CE (230 VAC): IEC-320-C14, 208 - 240 VAC

Power Inlet, 10 Amp Circuit Breaker.

Switched Plugs and Plug Indicators: Four AC Outlets that can be

switched On, Off, Rebooted or set to user-defined Default values in

response to user commands.
Model CMS-6R4: Four 100-120 VAC, NEMA 5-15 Outlets with

indicator lights. 15 Amps Total Load.

Model CMS-6R4-CE: Four 208-240 VAC, IEC-320-C13 Outlets with

indicator lights. 10 Amps Total Load.

Serial RS232 Ports: For connection to console ports on target devices.

Standard DB9 connectors configured as DTE ports, similar to a serial port

on a PC. When connecting a modem, use a standard serial cable. When

connecting a PC or other DTE device use a null modem cable.

Notes:

• Ports 1 is a System Setup Port. In order to ensure local access by

system administrators, Supervisor Level command capability cannot

be disabled at Port 1, and the Port Mode cannot be set to "Buffer" or

"Passive".

• Port 2 can also be used as a Setup Port, providing that the Port Mode

is set to Any-to-Any and the Supervisor Mode is enabled.

O

I

PHONE LINE

10BaseT

ACT

SYSTEM

SETUP

PORTS

15 AMPS

MAX

PLUG 1

PLUG 2

PLUG 3

PLUG 4

2

1

3

4

5

6

1

2

3

4

5

6

Figure 2.2: Back Panel Components (120 VAC Model Shown)

Advertising