Operation

6.6.4.

Terminating a Direct Connect Session

To terminate a Direct Connect session, use the client Telnet program's

"disconnect" feature. The following will occur immediately upon a client

initiated disconnect:
1. The Network port is disconnected from the RS232 Port.
2. The Network session is terminated.
3. The RS232 Port is put to sleep.

Notes:

• The Sequence Disconnect Command, which is defined via the Port

Configuration menus (Section 5.5.3) cannot be used to terminate a

Direct Connection.

• Any CMS-6R4 port that has accessed Command Mode using a

password that permits access to Supervisor Level commands can

terminate a direct connection at another port by issuing the /D

command as described in Section 6.2.3.2.

• Acknowledgment of data received by the CMS-6R4 network port

does not indicate that the data has been completely sent out the

serial port. Data may still be queued in the CMS-6R4 buffers.

Any data queued in the CMS-6R4 at the time of a client initiated

disconnect is discarded, and is not passed through to the attached

device.