4. Use your communication program's (e.g., HyperTerminal) upload/send

function to transfer the upgrade to the CMS-6R4 unit. Select ASCII

format, then specify the filename and directory location where the

firmware upgrade file resides on your hard drive.
Note:

The Upload function will timeout after one minute of

inactivity. If the function times out, reselect the desired upload option

as described in Step 3 and press [Enter] to continue or [Esc] to abort.

5. If the upload is successful, the CMS-6R4 will prompt the user to continue

the upgrade or abort.
1. Upgrade: To continue with the upgrade, type

1 and press [Enter].

The CMS-6R4 will erase the previous firmware, move new firmware

from SRAM to program flash memory, calculate and store the new

checksum, and reboot. Do not attempt to reconnect to the unit until

the RDY indicator blinks to indicate the process is complete.

2. Abort: To abort the procedure, type

2 and press [Enter].

6. Incomplete Upload: If the upload is interrupted, times-out, or if the

update file becomes corrupted during transfer, the CMS-6R4 will display

a screen which asks for confirmation before proceeding. To proceed, type

1 and press [Enter], then return to Step 4 above to retry the upload, or

press [Esc] to reboot the CMS-6R4 unit.

7. Recovery Mode: In the rare event that the CMS-6R4 operating system

becomes corrupted during installation, front panel indicators will blink,

and the unit will automatically switch to Recovery Mode. For further

instructions, please contact WTI Customer Service as described in

Appendix C.

When firmware upgrades are offered, an updated Users Guide or addendum

will also be available.