State Industries SANDBLASTER SBD85 500 User Manual

Page 12

Advertising
background image

SBD TANK TYPE HEATERS

SERVICE HANDBOOK

Technical Training Department

Ashland City, TN ©2003

11

SBD GAS VALVE

The gas valves used on all SBD water heaters are

24 volt AC combination step opening gas valves.

They incorporate the pilot valve, main valve, and gas

pressure regulators into one body. The inlet view of

the valve features a filter screen and the top knob.

The top knob is a manual on/off gas control for both

the pilot and main gas valves. When the top knob is

placed on the black mark, gas is supplied only to the

pilot valve.

On the top view, we see the pilot solenoid and

pilot and main gas regulators. The top view also

displays the “TH and “TR” terminals. The pilot

gas regulator is found under its cover screw. It is

factory preset at 3.5” W.C. but can be adjusted from

2.5 to 5 inches water column. The main gas

regulator is found under its cover screw. It is

factory preset to 3.5 inches W.C. and adjusts gas

pressure output from 2.5 to 5 inches water

column. The two electrical terminals are marked

TH and TR. The TH terminal is the common

between the pilot valve solenoid coil and the main

valve solenoid coil. The other wire emerging from

the pilot solenoid connects to the pilot valve

electrical output on the IID (terminal PV). The TR

terminal connects directly to the main valve

electrical output from the IID module

(terminal MV).

On the outlet view of the gas valve, we see the

pilot gas connection port, manifold gas connection

port, a limited bleed vent port, the manifold gas and

pressure tap.

See step 18 for SBD-500 gas valve illustration