Component part information – State Industries SANDBLASTER SBD85 500 User Manual

Page 52

Advertising
background image

SBD TANK TYPE HEATERS

SERVICE HANDBOOK

Technical Training Department

Ashland City, TN ©2003

51

COMPONENT PART INFORMATION

NAME

SPECIFICATIONS

DUAL

CONTROLLER

THERMOST

AT

120-180

O

RANGE, + 4

O

, 5

O

DIFFERENTIAL,

LIQUID FILLED, ANTI-

STACKING

HIGH LIMIT

(ECO)

OPENS - 205

O

FIXED, MANUAL

RESET BELOW 185

O

GAS VALVE

NATURAL

GAS

SBD 120-400;24VAC, 60hz,

.6A,.7” to 3.5” W.C.,

STEP OPEN

SBD 500; 24VAC, 60hz, Dual

Gas Valve,

STEP OPEN

PROPANE

GAS

SBD 120-400;

2.5 – 10” W.C.

STEP OPEN

SBD 500; 24VAC, 60hz, Dual

Gas Valve,

STEP OPEN

INTERMITENT

IGNITION

DEVICE

CONTROL

NATURAL

GAS AND

PROPANE

GAS

24 VAC, 50-60 HZ, .1A;

.7 MICROAMP SIGNAL

CONTINUOUS RETRIAL

DAMPER

COMPLETE

ASSEMBLY

MOTOR

24 VAC, 60 HZ, 120 RPM, 5

WATT

(NOT 110, 111 SERIES)

P.C. BOARD

W/RELAY

Service Switch

(NOT 110, 111 SERIES)

TRANSFORMER

120 V PRIMARY, 24 VAC

SECONDARY,

40 VA, 50-60 HZ, CLASS 2 "B"