SBD TANK TYPE HEATERS

SERVICE HANDBOOK

Technical Training Department

Ashland City, TN ©2003

19

TROUBLESHOOTING SBD WATER HEATERS

To troubleshoot a SBD water heater check that:

• 120 VAC is supplied to the heater

• the tank is full of water

• gas is supplied to the unit

STEP 1

TEST THE TRANSFORMER

STEP 1 - TO TEST THE TRANSFORMER - Using a multimeter, test for 24 VAC

between the secondary transformer terminals.

N

E

H

T

F

I

The meter does not read 24 VAC:

• Check that the 120 VAC is supplied

from the On/Off Switch – if not, replace

switch.

• Check that the 120 VAC is supplied

from transformer.

The meter reads 24 VAC:

• Go to step 2.