State Industries SANDBLASTER SBD85 500 User Manual

Page 34

Advertising
background image

SBD TANK TYPE HEATERS

SERVICE HANDBOOK

Technical Training Department

Ashland City, TN ©2003

33

STEP 13

PILOT SPARK TEST

STEP 13. PILOT SPARK TEST. Visually check for spark at the pilot assembly.

Note: The pilot burner mounts on the left side of the main burner.

N

E

H

T

F

I

The igniter is not sparking:

Check for:

• A 7/64” spark gap

• Spark cable continuity

• Ground cable continuity

Sparking is present:

• Go to step 14.

Power To Module May Be Interrupted To Reset .

Trial for Ignition

90 sec.

5 min.

90 sec.

5 min.

90 sec.

Call for

heat

Sparking

No

Sparking

Sparking

No

Sparking

Sparking

Continuous

Trial

Sequence

Advertising