Th tr – State Industries SANDBLASTER SBD85 500 User Manual

Page 40

Advertising
background image

SBD TANK TYPE HEATERS

SERVICE HANDBOOK

Technical Training Department

Ashland City, TN ©2003

39

STEP 18A

MAIN GAS VALVE CHECK

SBD 120 – 400 GAS VALVE

STEP 18A. MAIN GAS VALVE CHECK. Disconnect wires from gas valve TH and TR

terminals. Using a multimeter, test for 68 ohms plus or minus 5 between TH and TR on

the main valve coil.

N

E

H

T

F

I

The meter reads ‘O’ or infinity

• Replace the gas valve

The meter reads 68* ohms plus or minus 5 • The main burner will ignite

TH

TR

Advertising