SBD TANK TYPE HEATERS

SERVICE HANDBOOK

Technical Training Department

Ashland City, TN ©2003

22

STEP 4

INSPECT THE DAMPER

STEP 4. INSPECT THE DAMPER. Lower the thermostat setting so the unit will not be

calling for heat, then inspect the damper.

N

E

H

T

F

I

If the damper is open:

• Go to step 5.

If the damper is closed:

• Go to step 7.

Note: If the water temperature in the tank is below 120 degrees F, temporarily disconnect the

jumper wire between the high limit and thermostat to simulate a satisfied thermostat.

STEP 5

CHECK THE PC BOARD

STEP 5. CHECK THE PC BOARD. Test for 24 VAC between the black PC board wire

connection and ground.

N

E

H

T

F

I

24 VAC is not present:

• Check the black wire connections

between PC Board and high limit.

24 VAC is present:

• Go to step 6.