SBD TANK TYPE HEATERS

SERVICE HANDBOOK

Technical Training Department

Ashland City, TN ©2003

24

STEP 7

THERMOSTAT TEST

STEP 7. THERMOSTAT TEST. Set the thermostat to call for heat. Using your

multimeter, test for 24 VAC between right terminal and ground.

N

E

H

T

F

I

The meter does not read 24 VAC and the jumper wire

between the high limit and the thermostat is in place:

• Replace the thermostat

The meter reads 24 VAC:

• Go to step 8.

Note: If the high limit to thermostat jumper wire was disconnected earlier to simulate a satisfied

thermostat, reconnect the jumper to the terminals.

Note: A yellow wire from this thermostat terminal connects to the damper PC board.