CLOCK & POWER MANAGEMENT

S3C2440A RISC MICROPROCESSOR

7

-20

CLOCK GENERATOR & POWER MANAGEMENT SPECIAL REGISTER

LOCK TIME COUNT REGISTER (LOCKTIME)

Register Address R/W

Description

Reset

Value

LOCKTIME

0x4C000000

R/W

PLL lock time count register

0xFFFFFFFF


LOCKTIME Bit

Description

Initial

State

U_LTIME

[31:16] UPLL lock time count value for UCLK.

(U_LTIME 300uS)

0xFFFF

M_LTIME

[15:0]

MPLL lock time count value for FCLK, HCLK, and PCLK
(M_LTIME 300uS)

0xFFFF

MPLL Control Register

Mpll = (2 * m * Fin) / (p * 2

s

)

m = (MDIV + 8), p = (PDIV + 2), s = SDIV

UPLL Control Register

Upll = (m * Fin) / (p * 2

s

)

m = (MDIV + 8), p = (PDIV + 2), s = SDIV

PLL Value Selection Guide (MPLLCON)

1. F

out

= 2 * m * Fin / (p*2

s

), F

vco

= 2 * m * Fin / p where : m=MDIV+8, p=PDIV+2, s=SDIV

2. 600MHz

F

VCO

1.2GHz

3. 200MHz

FCLK

OUT

600MHz

4. Don't set the P or M value as zero, that is, setting the P=000000, M=00000000 can cause malfunction of

the PLL.

5. The proper range of P and M: 1 ≤ P ≤ 62, 1 ≤ M ≤ 248

NOTE

Although there is the rule for choosing PLL value, we recommend only the values in the PLL value recommendation
table. If you have to use another value, please contact us.