S3C2440A RISC MICROPROCESSOR

CAMERA INTERFACE

23-9

TIMING DIAGRAM FOR LAST IRQ

IRQ except LastIRQ is generated before image capturing. Last IRQ which means capture-end can be set by

following timing diagram. LastIRQEn is auto-cleared and ,as mentioned, SFR setting in ISR is for next frame

command. So, for adequate last IRQ, you should follow next sequence between LastIRQEn and ImgCptEn

/ImgCptEn_CoSc /ImgCptEnPrSC. It is recommended that ImgCptEn /ImgCptEn_CoSc /ImgCptEnPrSC are set at

same time and at last of SFR setting in ISR. FrameCnt which is read in ISR, means next frame count. On following

diagram, last captured frame count is “1”. That is, Frame 1 is the last-captured frame among frame 0~3. FrameCnt

is increased by 1 at IRQ rising.