I/O PORTS
S3C2440A RISC MICROPROCESSOR
9-30
EINT17
[6:4]
Setting the signaling method of the EINT17.
000 = Low level
001 = High level
01x = Falling edge triggered
10x = Rising edge triggered
11x = Both edge triggered
000
FLTEN16
[3]
Filter Enable for EINT16
0 = Filter Disable
1= Filter Enable
0
EINT16
[2:0]
Setting the signaling method of the EINT16.
000 = Low level
001 = High level
01x = Falling edge triggered
10x = Rising edge triggered
11x = Both edge triggered
000