S3C2440A RISC MICROPROCESSOR

ADC AND TOUCH SCREEN INTERFACE

16-5

ADC AND TOUCH SCREEN INTERFACE SPECIAL REGISTERS

ADC CONTROL REGISTER (ADCCON)

Register Address R/W

Description

Reset

Value

ADCCON

0x5800000

R/W

ADC Control Register

0x3FC4

ADCCON Bit

Description

Initial

State

ECFLG

[15]

End of conversion flag(Read only)
0 = A/D conversion in process
1 = End of A/D conversion

0

PRSCEN

[14]

A/D converter prescaler enable

0 = Disable
1 = Enable

0

PRSCVL [13:6]

A/D converter prescaler value
Data value: 0 ~ 255
NOTE: ADC Freqeuncy should be set less than PCLK by 5times.
(Ex. PCLK=10MHZ, ADC Freq.< 2MHz)

0xFF

SEL_MUX

[5:3]

Analog input channel select
000 = AIN 0
001 = AIN 1
010 = AIN 2
011 = AIN 3
100 = YM
101 = YP
110 = XM
111 = XP

0

STDBM

[2]

Standby mode select
0 = Normal operation mode
1 = Standby mode

1

READ_ START

[1]

A/D conversion start by read
0 = Disable start by read operation
1 = Enable start by read operation

0

ENABLE_START

[0]

A/D conversion starts by enable.
If READ_START is enabled, this value is not valid.
0 = No operation
1 = A/D conversion starts and this bit is cleared after the start-up.

0

NOTE : When Touch Screen Pads(YM, YP, XM, XP) are disabled, these ports can be used as Analog input