8.11 Changing the Twinax Timeout Value (For
Reference Only)

If necessary you can change the Twinax Timeout value by following these steps:

1.

Press Menu> until NETWORK MENU displays. Press Select.

2.

Press Menu> until NETWORK OPTION 1, NETWORK OPTION 2 or
NETWORK OPTION 3 displays. The number corresponds to the number
of the option connector the Adapter for SCS occupies. Press Select.

3.

Press Menu> until you see SCS MENU 1, SCS MENU 2 or SCS MENU
3
. Press Select.

4.

Press Menu> until you see SCS OPTIONS. Press Select.

5.

Press Menu> until you see Twinax Timeout. Press Select. The default is 10
seconds. You can specify how long the adapter will wait before closing the
connection to the host.

8.12 Twinax device description

When you let the AS/400 auto-create your IPDS device, you will need to alter the
following parameters to enable full IPDS printing:

"default" values:

Advanced Function Printing

AFP

*NO

Form Feed

FORMFEED

*CONT

"altered" values:

Advanced Function Printing

AFP

*YES

Form feed

FORMFEED

*AUTOCUT