7.2.2 Setting the MarkNet Internal Print Server Job Timeout

The recommended setting for the MarkNet internal print server Job Timeout is 0
(disabled). This allows the host system "release timer" value and the printer IPDS
Timeout
value to control when print jobs from another protocol, interface, server, or
host can be started.

You may set the MarkNet internal print server Job Timeout value to a value greater
than the host "release timer" value. Errors are very likely to occur when the printer
requires user intervention and the intervention is not cleared before the timeout occurs.

Setting the MarkNet internal print server Job Timeout smaller than the host "release
timer" value or the printer IPDS Timeout value will result in communication errors
after the job has printed.

From the printer operator panel, do the following:

1.

Press Menu> until the NETWORK MENU displays. Press Select.

2.

Press Menu> until the NETWORK OPTION 1 displays. Press Select.
(This example assumes the MarkNet internal print server is installed in
option connector 1.)

3.

Press Menu> until you see NETWORK 1 SETUP. Press Select.

4.

Press Menu> until you see NETWORK CARD. Press Select.

Here you find the following setting:

Job Timeout

0

(A setting of 0 allows the host system timer or the printer IPDS Timeout value to
control when print jobs from another protocol, interface, server or host can be started.)