Pitney Bowes J640 User Manual

Page 101

Advertising
background image

Example

{I,E,"~123~063~034~124~125~126~094"

p

}

This record would

change only the parameter separator character to ?.
The other control characters would remain unchanged.

enable the immediate commands, using the ^ symbol
as the command identifier.

n

The

I

parameter is only needed if you send these records

separately. (If you are sending multiple records, the

I

parameter is only needed once.)

Resetting Control Characters

You can change the characters in the previous example back
to their original settings by downloading this packet:

{I?E?"~123~044~034~124~125~126~094"

p

}

Notice that the parameter separator is ? in this packet. This is
the parameter separator that was set before this packet. Once
the packet is received by the printer, the new parameter
separator (a comma, in this case) is valid.

n

Be careful when using this feature. If you forget what the
control characters were changed to, print a test label. (The
test label lists the current control characters.) Refer to
Chapter 10, "Diagnostics," for details on printing a test label.

Co

nf
igu

ring

t

h

e P

rin
te

r

Chapter 5. Configuring the Printer

5-15

Advertising