Pitney Bowes J640 User Manual

Page 117

Advertising
background image

Standard Syntax Guidelines

When creating MPCLII packets

✦

Begin each packet with a Start of Packet.

✦

End each packet with an End of Packet.

✦

Define no more than 100 fields in a format.

✦

Define all fields in the order you want to image/print
them. The printer does not print in field number order.

✦

Separate all parameters with a Parameter Separator.

✦

End each field with a Field Separator.

✦

Enter all information in CAPITAL letters, except words
or phrases within quotation marks.

✦

Include all parameters for a field unless documented as
optional.

✦

Define non-printable text fields immediately before the
field to which they apply.

✦

Define options immediately after the field to which they
apply.

✦

Multiple options can be used with most fields. Options
can be used in any combination except as noted with
each definition.

✦

Keep in mind that proportionally spaced fonts need
wider fields than monospaced fonts.

✦

Do not place a new line (return) or any other
non-printing character in a character string.

✦

Spaces are ignored, except within character strings.

✦

Use a tilde (~) followed by a 3-digit ASCII code in a
quoted string to send function codes or extended
characters or send the 8-bit ASCII code.

✦

Enter fields in numerical order.

J640 Programmer’s Manual