Pitney Bowes J640 User Manual

Page 93

Advertising
background image

Example

{I,A,0,0,1,1,0

p

}

This record would

✦

identify the system setup record.

✦

power up the printer in the online mode.

✦

use the default prompt value.

✦

print a separator after each batch.

✦

print zeros with slashes through them.

✦

use the internal symbol set.

n

The

I

parameter is only needed if you send these records

separately. (If you are sending multiple records, the

I

parameter is only needed once.) You must resend the format
to the printer before the batch separator, slashed zero, and
symbol set changes take effect.

Record B: Supply Setup

Use the Supply Setup record to select

✦

the type of supply to use.

✦

ribbon installation.

✦

how the supply feeds through the printer.

✦

the supply position.

Use the following syntax for the Supply Setup record:

Syntax

{I,B,supply_type,ribbon_on,feed_mode,
supply_posn

p

}

Co

nf
igu

ring

t

h

e P

rin
te

r

Chapter 5. Configuring the Printer

5-7

Advertising