Defining text fields – Pitney Bowes J640 User Manual

Page 119

Advertising
background image

Defining Text Fields –––––––––––––––––––––––––––––––––––––––––

Example

T,2,10,V,250,50,0,1,1,1,B,C,0,0,0

p

Syntax

T,field#,# of char,fix/var,row,column,gap,font,
hgt mag wid mag,color,alignment,char rot,
field rot,sym set

p

T1. T

Indicates a text field. Enter T.

T2. field #

Unique number from 0-99 to identify this field. (Pitney
Bowes recommends starting at 1, instead of 0.)

T3. # of char

Maximum number of printed characters (1-2710) in the
field.

T4. fix/var

Fixed or variable length field. Options:

F

Fixed length

V

Variable length

T5. row

For monospaced fonts, distance from bottom of print area
to lower left corner of field. For proportionally spaced
fonts, distance from bottom of print area to baseline of
characters in field. (Bottom exits the printer first.) Ranges:

English

0 - 599

Metric

0 - 1523

Dots

0 - 1151

T6. column

Distance to lower left corner of field, from left edge of
print area. Ranges:

English

0-399

Metric

0-1014

Dots

0-767

T7. gap

Number of dots between characters. Ranges: 0-99.

J640 Programmer’s Manual

7-4

Advertising